LK Armatur LK Group English
Close

LK Group

CP Expansion Vessel

CP Expansion Vessel

Expansion vessel for heating, recovery and cooling systems.

CP Expansion Vessel

Variants

CP

CP 6 variants

Manufacturing standards: Expansion vessels manufactured in accordance with the European Directive PED 97/23 and the Swedish Pressure Vessels Directive AFS 1999: 4.

Article Dim. A mm Note Weight (kg) Dimensional sketch Item List
552 33 23 6 liter 118 B1 / B2: 300 / 325 3.2
552 33 24 8 liter 132 B1 / B2: 300 / 325
552 33 25 10 liter 150 B1 / B2: 300 / 325
552 33 26 12 liter 170 B1 / B2: 300 / 325 3.7
552 33 31 14 liter 170 B1 / B2: 360 / 387 5.0
552 33 32 18 liter 186 B1 / B2: 360 / 387 5.3

552 33 23

Dim. 6 liter
A mm 118
Note B1 / B2: 300 / 325
Weight (kg) 3.2
Dimensional sketch
Item list

552 33 24

Dim. 8 liter
A mm 132
Note B1 / B2: 300 / 325
Weight (kg)
Dimensional sketch
Item list

552 33 25

Dim. 10 liter
A mm 150
Note B1 / B2: 300 / 325
Weight (kg)
Dimensional sketch
Item list

552 33 26

Dim. 12 liter
A mm 170
Note B1 / B2: 300 / 325
Weight (kg) 3.7
Dimensional sketch
Item list

552 33 31

Dim. 14 liter
A mm 170
Note B1 / B2: 360 / 387
Weight (kg) 5.0
Dimensional sketch
Item list

552 33 32

Dim. 18 liter
A mm 186
Note B1 / B2: 360 / 387
Weight (kg) 5.3
Dimensional sketch
Item list

Detailed Information

Description

Expansion vessel for heating, recovery and cooling systems.

Expansion Vessels must be installed according to instructions in VVA 93. The expansion vessel is inspected visually prior to installation. When installing with a system, the pre-pressure must be adjusted so that it matches the static pressure prevailing at the tank’s connection point. The adjustment takes place without the influence of system pressure (depressurised on the system side).

The expansion vessel does not require maintenance. Air valve must be provided with protective covering.

Technical Data

Max. working pressure: 3.0 bar
Working temperature: Min. –10 °C / Max. 70 °C
Maximum instantaneous temperature: 110 °C
Media 1: Water - Glycol mixture max. 50%
Other data: Material, vessel Closed expansion vessel in steel.
Material, internal membrane SBR rubber
Pre-charge of the vessels 0.5 bar. Other pre-charge on request.

Questions & Answers

Which expansion vessel should I buy?

If your expansion vessel connection is located on the long side, you should choose expansion vessel article number: 064010. If your expansion vessel connection is located on the short side, you should choose expansion vessel article number: 5523321